NETBACKUP OPSCENTER "Error occurred while connecting to the OpsCenter Server. Please ensure that the server is running"


1) Update hosts file with the server's short and FQDN name
2) Stop OpsCenter services:
<install_path>\OpsCenter\server\bin>opsadmin stop
Stopping the OpsCenter Web Console Service...
Stopping the OpsCenter Server...
Stopping the OpsCenter database...
3) Start OpsCenter services:
 <install_path>\OpsCenter\server\bin>opsadmin start
Starting the OpsCenter Database...
The Symantec OpsCenter Database Server service is starting.
The Symantec OpsCenter Database Server service was started successfully.
Starting the OpsCenter Server...
The Symantec OpsCenter Server Service service is starting.
The Symantec OpsCenter Server Service service was started successfully.
Starting OpsCenter Web Console Service...
The Symantec OpsCenter WebServer Service service is starting.
The Symantec OpsCenter WebServer Service service was started successfully.